Nama Tes Standar Dicapai Hasil
Combustibility
Fire Properties (50mm)
1. Ignitability
2. Fire Propagation Index
3. Surface Spread of Flame Fire Resistance (50mm)
Fire Resistance (75mm)
Ignition Index
Heat Evolved Index
Flame Spread Index
Smoke Developed Index
Smoke Emission & Toxic Gas Distillation
AS1530, PART 1
BS476, PART 5
BS476, PART 6
BS476, PART 7
AS1530, PART 4, BS476, PART 20 & 21
AS1530, PART 4, BS476, PART 20 & 22
AS1530, PART 3
AS1530, PART 3
AS1530, PART 3
AS1530, PART 3
CSIRO (NBTC) SYDNEY
Non‐combustible
‘P’
0
Class – 1
60 MINUTES
120 MINUTES
0
0
0
0‐1
None recorded
Sound Insulation (50mm)
Sound Insulation (75mm)
Acoustic Evaluation (50mm)
Acoustic Evaluation (50mm)
50mm with air cavity & 13mm plasterboard
*Additional Qpanel acoustic results with cavities & cladding available on request.
ISO140‐3, ISO140‐4
ISO140‐3, ISO140‐4
AS1191, BS2750, PART 3, BS5821, PART 1
AS1191, BS2750, PART 3, BS5821, PART 1
CURTIN UNIVERSITY WEST AUSTRALIA
STC – 37
STC – 39
STC – 33
STC – 38
STC – 45
Thermal Conductivity (50mm)
Thermal Conductivity (75mm)
BS874, PART 2
BS874, PART 2
0.23 W/m°K
0.33 W/m°K
Flexural – 4 Point Bend Test (50mm)
Flexural – 4 Point Bend Test (75mm)
Average Flexural Strength (75mm)
COLLEGE OF ENGINEERING (JNTU)
COLLEGE OF ENGINEERING (JNTU)
INSTITUTE OF TECHNOLOGY (MADRAS)
23.6 kg/cm²
15.5 kg/cm²
3.00 MPa
Lightweight Construction BUILDING CODE OF AUSTRALIA C1.8 Exceeds Requirements
Axial Compression (50mm)
- Breaking Load
- Allowable Axial Load/m
- Axial Compression (75mm)
- Breaking Load
- Allowable Axial Load/m
COLLEGE OF ENGINEERING (JNTU)
COLLEGE OF ENGINEERING (JNTU)
9,573.3 Kgs
127.6 KN/m
13,233.3 Kgs
176.4 KN/m
Anchor Tests (Pullout Test)
Anchor Tests (Shear Test)
BS5080, PART 1 & 2
BS5080, PART 1 & 2
4.36kN
7.40kN
Resistance to Air & Water (50mm) – A
Resistance to Air & Water (50mm) – B
Resistance to Air & Water (50mm) – C
Water Absorption (50mm)
Moisture Content (50mm)
Swelling in Water (50mm)
Water Absorption (75mm)
Moisture Content (75mm)
Swelling in Water (75mm)
Water Penetration
Water Penetration
Water Resistance (50mm)
Water Resistance (75mm)
Permeability Test (Panel and Joint)
BS4315, PART 2
BS4315, PART 2
BS4315, PART 2
IS2380 – 16
IS2380 – 3
IS2380 – 17
IS2380 – 16
IS2380 – 3
IS2380 – 17
UNIVERSITY OF WESTERN AUSTRALIA
INSTITUTE OF TECHNOLOGY (MADRAS)
BS4315, PART 2
BS4315, PART 2
CURTIN UNIVERSITY WEST AUSTRALIA
No Dampness
8.89%
No Leakage
3.95%
9.1%
NIL
1.65%
8.7%
NIL
NIL
NIL
No Penetration
No Penetration
No Ingress of Water
Modulus of Rupture (50mm) Dry
Modulus of Rupture (50mm) Wet
Modulus of Rupture (75mm) Dry
Modulus of Rupture (75mm) Wet
IS2380 – 4
IS2380 – 4
IS2380 – 4
IS2380 – 4
5.39 N/mm²
3.85 N/mm²
3.81 N/mm²
2.94 N/mm²
Modulus of Elasticity (50mm)
Modulus of Elasticity (75mm)
IS2380 – 4
IS2380 – 4
9216 N/mm²
3072 N/mm²
Strength and Robustness Tests
‐ Partition Stiffness
‐ Small Hard Body Impact (6Nm)
‐ Small Hard Body Impact (15Nm)
‐ Large Soft Body Impact (40 & 120Nm)
‐ Door Slamming
‐ Crowd Pressure (2kN/m)
‐ Lightweight Anchorage:
i. Pullout (100N)
ii. Pulldown (250N)
‐ Heavyweight Anchorage:
i. Pulldown (3kN/m)
BS5234, PART 2
BS5234, PART 2
BS5234, PART 2
BS5234, PART 2
BS5234, PART 2
BS5234, PART 2
BS5234, PART 2
BS5234, PART 2
BS5234, PART 2
No Weakness
No Weakness
No Weakness
No Damage
No Visible Cracks
No Damage
Retained
Retained
Retained
Tensile Strength (50mm) Dry
Tensile Strength (50mm) Aged
Tensile Strength (75mm) Dry
Tensile Strength (75mm) Aged
IS2380 – 5
IS2380 – 5
IS2380 – 5
IS2380 – 5
0.48 N/mm²
0.47 N/mm²
0.42 N/mm²
0.35 N/mm²
Compressive Strength (75mm)
INSTITUTE OF TECHNOLOGY (MADRAS) 2.75 Mpa
Intruder Resistance
(50mm with Lamination)
AS3555 Level 1
Simultaneous Determination of: Ignitability Index
Spread of Flame Index
Heat Evolved Index
Smoke Developed Index
(All 50mm with Lamination)
AS1530, PART 3
AS1530, PART 3
AS1530, PART 3
AS1530, PART 3
0
0
0
0-1
Wall Height (Fire and Non‐Fire Rated) CSIRO REPORT FCO 0505 Up to 4200mm
Live Load Test
AS1170, PART 1 8.0mm
Biological – E Board
ETERNIT EVEREST No Fungus Growth
Accelerated Weathering Cycle – E Board
ETERNIT EVEREST No Deterioration
pH Value (50mm)
pH Value (75mm)
IS2380
IS2380
12
12

* Data uji panel AudiePanel® ini terdiri dari informasi yang dikumpulkan dari sertifikat yang berkaitan dengan AudiePanel® VI dan AudiePanel® VII. Data panel individu mungkin sedikit berbeda. Silahkan hubungi kami untuk lembar data terbaru.